RR KABELS

RR KABLES
68 items

POWER CABLES-A2XFY/2XFY-A2XWY/2XWY-4 CORE

Cable Construction 1.1 kV (A.C) & 1.5 kV (D.C ) to Earth4 cores AL / CU conductor, XLPE insul...

Cable Construction 1.1 kV (A.C) & 1.5 kV (D.C ) to Earth4 cores AL / CU conductor, XLPE insulated, galvanised steel strip / wire armoured cables as per IS 7098 Part - 1.Conductor : AL up to 10 Sq. mm conductor are solid Cl. 1 as per IS 8130. And above 10 Sq. mm conductor are stranded compacted shape Cl. 2 as per IS 8130In CU 4 & 6 Sq. mm conductor are solid Cl. 1 or stranded Cl. 2 as per IS 8130. 10 Sq. mm conductor is stranded Cl. 2, round as per IS 8130. Above 10 Sq. mm conductor ar...

Rs. 0.00

POWER CABLES-POWER CABLE-BS 5467

Application Industrial wiring and mains distribution. Can be laid direct in the ground, or in duc...

Application Industrial wiring and mains distribution. Can be laid direct in the ground, or in ducts, clipped to surface, on trays or in free air. May be embedded in concrete. Standard BS 5467 Technical Data Voltage Rating : 600/1000VMinimum Bending Radius : 15 x Cable diameterMaximum Conductor Temperature : 90°C Cable Construction Single, two, three, four and five core cables. Stranded plain copper conductors, XLPE insulated, cores laid up, extruded PVC bedding,galvanised steel wire armoured ...

Rs. 0.00

POWER CABLES-A2XY/2XY-1 CORE

Cable Construction 1.1 kV (A.C) & 1.5 kV (D.C ) to Earth1 cores AL / CU conductor, XLPE insul...

Cable Construction 1.1 kV (A.C) & 1.5 kV (D.C ) to Earth1 cores AL / CU conductor, XLPE insulated, unarmoured cables as per IS 7098 Part - 1.Conductor : AL up to 10 Sq. mm conductor are solid Cl. 1 as per IS 8130. And above 10 Sq. mm conductor are stranded round or compact Cl. 2 as per IS 8130In CU 4 & 6 Sq. mm conductor are solid Cl. 1 or stranded Cl. 2 as per IS 8130. 10 Sq. mm & above stranded round or stranded compact Cl. 2 as per IS 8130Insulation : Crosslinked polyethylene (...

Rs. 0.00

POWER CABLES-YY/YFY/YWY-2.5 Sq. mm

Cable Construction 1.1 kV (A.C) & 1.5 kV (D.C ) to Earth2.5 Sq. mm copper conductor, PVC insu...

Cable Construction 1.1 kV (A.C) & 1.5 kV (D.C ) to Earth2.5 Sq. mm copper conductor, PVC insulated unarmoured & galvanised steel strip / wire armoured control cables as per IS 1554 Part - 1.Conductor : CU conductor solid as per Cl .1 IS 8130 or stranded as per Cl. 2 IS 8130Insulation Material : PVC Type - A as per IS 5831/ Option : HR PVC (Type - C) as per IS 5831. Nominal thickness of insulation is 0.9 mmCore Colours : Up to 5 cores by colour coding & more than 5 cores number pri...

Rs. 0.00

POWER CABLES-YY/YFY/YWY-1.5 Sq. mm

Cable Construction 1.1 kV (A.C) & 1.5 kV (D.C ) to Earth2 cores AL / CU conductor, PVC insula...

Cable Construction 1.1 kV (A.C) & 1.5 kV (D.C ) to Earth2 cores AL / CU conductor, PVC insulated, galvanised steel strip / wire armoured cables as per IS 1554 Part - 1.Conductor : AL up to 10 Sq. mm conductor are solid Cl. 1 as per IS 8130. And above 10 Sq. mm conductor are stranded round or compact round or compact shape conductor Cl. 2 as per IS 8130In CU 4 & 6 Sq. mm conductor are solid Cl. 1 or stranded round Cl. 2 as per IS 8130. 10 Sq. mm conductor is stranded round or stranded ...

Rs. 0.00

POWER CABLES- AYFY/YFY-AYWY/YWY-2 CORE

Cable Construction 1.1 kV (A.C) & 1.5 kV (D.C ) to Earth2 cores AL / CU conductor, PVC insula...

Cable Construction 1.1 kV (A.C) & 1.5 kV (D.C ) to Earth2 cores AL / CU conductor, PVC insulated, galvanised steel strip / wire armoured cables as per IS 1554 Part - 1.Conductor : AL up to 10 Sq. mm conductor are solid Cl. 1 as per IS 8130. And above 10 Sq. mm conductor are stranded round or compact round or compact shape conductor Cl. 2 as per IS 8130In CU 4 & 6 Sq. mm conductor are solid Cl. 1 or stranded round Cl. 2 as per IS 8130. 10 Sq. mm conductor is stranded round or stranded ...

Rs. 0.00

POWER CABLES- AYFaY/YFaY-AYWaY/YWaY

Cable Construction 1.1 kV (A.C) & 1.5 kV (D.C ) to Earth1 cores AL / CU conductor, PVC insula...

Cable Construction 1.1 kV (A.C) & 1.5 kV (D.C ) to Earth1 cores AL / CU conductor, PVC insulated, aluminum steel strip / wire armoured cables as per IS 1554 Part - 1.Conductor : AL up to 10 Sq. mm conductor are solid Cl. 1 as per IS 8130. And above 10 Sq. mm conductor are stranded round or compact Cl. 2 as per IS 8130In CU 4 & 6 Sq. mm conductor are solid Cl. 1 or stranded Cl. 2 as per IS 8130. 10 Sq. mm & above stranded round or stranded compact Cl. 2 as per IS 8130Insulation : P...

Rs. 0.00

POWER CABLES- AYY/YY-4 CORE

Cable Construction 1.1 kV (A.C) & 1.5 kV (D.C ) to Earth4 cores AL / CU conductor, PVC insula...

Cable Construction 1.1 kV (A.C) & 1.5 kV (D.C ) to Earth4 cores AL / CU conductor, PVC insulated, unarmoured cables as per IS 1554 Part - 1.Conductor : AL up to 10 Sq. mm conductor are solid Cl. 1 as per IS 8130. And above 10 Sq. mm conductor are stranded compacted shape Cl. 2 as per IS 8130In CU 4 & 6 Sq. mm conductor are solid Cl. 1 or stranded Cl. 2 as per IS 8130. 10 Sq. mm conductor is stranded Cl. 2 round as per IS 8130. Above 10 Sq. mm conductor are stranded compacted shaped Cl...

Rs. 0.00

POWER CABLES- AYY / YY3.5 CORE

Cable Construction 1.1 kV (A.C) & 1.5 kV (D.C ) to Earth3.5 cores AL / CU conductor, PVC insu...

Cable Construction 1.1 kV (A.C) & 1.5 kV (D.C ) to Earth3.5 cores AL / CU conductor, PVC insulated, unarmoured cables as per IS 1554 Part-1. Conductor : AL / CU stranded compact shaped conductor as per Cl. 2, IS 8130 Insulation : PVC Type - A as per IS 5831. (Option : HR PVC Type - C, as per IS 5831) Phase Core Color : Red, yellow, blueNeutral Core Color : BlackInner Sheath : PVC / PVC tape as per IS 1554 (P - 1)Outer Sheath : PVC Type ST - 1 as per IS 5831 (Option : PVC Type ST - 2 as pe...

Rs. 0.00